Brand Name : HNMC
Model Number : HES-30
Place of Origin : China
MOQ : 1
Price : Negotiable
Supply Ability : 5 sets per month
Delivery Time : 30-45 days
Packaging Details : Wooden Package
Standard CT Class : 0.01S, 0.05, 0.02, 0.01...optional
Standard PT : 0.05 Class
Current Range : 5-5000A, or more for option
Voltage range : 6KV-220KV
Excitation Transformer : 10KVA
Rated Frequency : 50 or 60HZ
CT PT TEST Equipment System HES-30
Technical Parameter
HES-30 CT/PT Test Bench
| Input Voltage: | AC 220V±10%, 50Hz, Single-Phase | 
| Input Current: | AC 0-120A | 
| Rated Capacity: | 30kVA | 
| Output Voltage: | AC 0-250V | 
| Output Current: | AC 0-120A | 
HES-1Bx Transformer Tester
| Measure item: | Ratio errors & Phase errors of the CT and PT | 
| Rated current: | 5A, 1A | 
| Rated voltage: | 100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V | 
| Multiplier: | 1/√3, 1/3, 1, 1.5, 2 | 
| Accuracy class: | ±2% | 
| Operation range: | (1%-120%).In, (20%-120%).Un | 
| Frequency: | 50Hz or 60Hz | 
| Ratio error range: | ±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%). | 
| Minimum resolution:0.0001%. | |
| Phase error range: | 0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900') | 
| Minimum resolution: 0.01' | |
| Impedance range: | 0.001Ω~ 19.99Ω. | 
| Minimum resolution: 0.001Ω. | |
| Admittance range: | 0.001 ms ~ 19.99 ms. | 
| Minimum resolution:0.001 ms. | |
| Alarm Function: | Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent. | 
| 
 Input Load: | - On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0 - On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0 - On Standard PT secondary side: ≈0.05VA (100V) | 
| Communication Interface: | Provided the RS232 serial PC communication interface | 
| Display model: | LCD | 
| Power supply: | AC 220V±10%, 60Hz | 
| Power consumption: | < 20VA | 
| Product Type: | Portable type. | 
CT Burden FY47-49
| Rated Current: | 5A, 1A | 
| 
 Power Factor and Rated Burden: | In=5A: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA (more option available) In=1A: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA (more option available) | 
| Accuracy Class: | ±3% | 
| Operation Range: | (1%-120%). In | 
| Frequency: | 50Hz or 60Hz | 
| Withstand Voltage: | 2kV/1min | 
| Insulation: | Air | 
| Operating Model: | Short-time (Used in CT Accuracy Testing System) | 
| Product Type: | Portable type. | 
High-current Test Cables of the CT
Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc
500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs
HLB-50G1 Standard CT
| 
 Rated Primary Current(A): | 5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A (more option available) | 
| Rated Secondary Current: | 5A, 1A | 
| Rated Current Ratio: | 5A~5000A/5A, 5A~5000A/1A (more option available) | 
| Accuracy Class: | 0.01S% (0.05%, 0.02%, 0.01% or better are available) | 
| Rated Secondary Burden: | 0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A) | 
| Power Factor: | COSΦ=1.0 | 
| Operating Range: | (1%-120%). In | 
| 
 Connection Mode: | Fixed connection terminals at Pri.current range is 5A-450A Pass-through connection with 2 turns at Pri.current range is 500A-900A Pass-through connection with 1 turn at Pri.current range is 1000A-5000A | 
| Frequency: | 50Hz or 60Hz | 
| Voltage Level: | AC 600V | 
| Withstand Voltage: | 2000V 1min | 
| Insulating Medium: | Air | 
SLQ-30KVA Current Generator
| Input Voltage: | AC 0-250V | 
| Output Current: | AC 0-5000A | 
| Rated Capacity: | 30kVA | 
| Rated Input Current: | AC 120A | 
| Frequency: | 50Hz or 60Hz | 
| Current Output Model: | Fixed terminal at current is 50A, 200A, 500A Through-hole connection at current is 500A-5000A | 
| Products Shape: | Stainless Steel Box | 
| Working condition: | 0 - 40ºC, RH ≤ 90% | 
FY95-1 PT Burden
| Rated Voltage: | 100V, 100/√3V, 100/3V | 
| Power Factor: | COSФ=0.8, COSФ=1.0 | 
| Rated Burden (VA): | 1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA (more option available) | 
| Total Output Burden: | 308.75VA (more option available) | 
| Accuracy Class: | ±3% | 
| Operation Range: | (20%-120%). Un | 
| Frequency: | 50Hz or 60Hz | 
| Withstand Voltage: | 2kV/1min | 
| Insulation: | Air | 
| Operating Model: | Short-time (Used in PT Accuracy Testing System) | 
HJB-220G3 Standard PT
| Rated Primary Voltage: | 110/√3kV, 220/√3kV | 
| Rated Secondary Voltage: | 110V, 110/√3V, 100V, 100/√3V | 
| 
 Rated Voltage Ratio: | 110/√3/0.11/√3kV, 110/√3/0.11kV, 110/√3/0.1/√3kV, 110/√3/0.1kV 220/√3/0.11/√3kV, 220/√3/0.11kV, 220/√3/0.1/√3kV, 220/√3/0.1kV | 
| Accuracy Class: | 0.05% (100/√3V,110/√3V), 0.1% (100V,110V) | 
| Rated Secondary Burden: | 0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V) | 
| Power Factor: | COSΦ=1.0 | 
| Operating Range: | (20%-120%). Un | 
| Frequency: | 50Hz /60Hz | 
| Insulation: | SF6 Gas | 
HJC-80 Resonant High Voltage Source
| 
 Product Application: | The system is a voltage generator, and used for Capacitive PT accuracy testing with 110/√3kV and 220/√3kV voltage level | 
| Rated input voltage: | AC 220V | 
| Rated output voltage: | AC 0~200 kV | 
| Rated Capacity: | 200 kVar | 
| Max output current: | AC 1.0 A | 
| Frequency: | 50Hz or 60Hz | 
| The capacitance of the object CVT: | 0.004uF ~0.02uF | 
| Operating Condition: | Temperature: -10oC ~ +50 oC | 
| RH: up to 85% (max. 90%, non-condensing) | 
LCB-10KVA/10KV Exciting Transformer
| Input Voltage: | AC 0 - 250V, 50Hz | 
| Output Voltage: | AC 0 - 10kV, 50Hz | 
| Output Current: | AC 0-1A | 
| Rated Capacity: | 10kVA | 
| Insulation: | Dry type | 
| Weight: | ~ 50 kg | 
DKQ-40KVA/40KV Reactor
| Rated Capacity: | 40kVA/stage | 
| Rated Voltage: | AC 40 kV/stage | 
| Rated Current: | AC 1 A/stage | 
| Inductance Range: | 125H-500H/stage | 
| Insulation: | Epoxy resin casting | 
| Weight: | ~ 60 kg/stage | 
| Quantity: | 5pcs | 
|   | 
| 0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set Images | 
 CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                                                    
                        
                        
                        
                                                            CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                    
                        
                     Cabinet Type CT PT Test Equipment System Error Measurement
                                                                                    
                        
                        
                        
                                                            Cabinet Type CT PT Test Equipment System Error Measurement
                                                    
                        
                     0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                                                    
                        
                        
                        
                                                            0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                    
                        
                     0.02 Class CT PT Test Equipment , Low Current CT Test Kit
                                                                                    
                        
                        
                        
                                                            0.02 Class CT PT Test Equipment , Low Current CT Test Kit
                                                    
                        
                     4000A Current Transformer Tester In Magnetic Environment
                                                                                    
                        
                        
                        
                                                            4000A Current Transformer Tester In Magnetic Environment
                                                    
                        
                     0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                                                    
                        
                        
                        
                                                            0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                    
                        
                     0.2 Class CT PT Test Equipment Electromagnetic Type VT
                                                                                    
                        
                        
                        
                                                            0.2 Class CT PT Test Equipment Electromagnetic Type VT
                                                    
                        
                     0.02 Class CT PT Test Equipment
                                                                                    
                        
                        
                        
                                                            0.02 Class CT PT Test Equipment
                                                    
                        
                     0.05S CT PT Analyzer
                                                                                    
                        
                        
                        
                                                            0.05S CT PT Analyzer
                                                    
                        
                     Phase Angle Error CT PT Test Set
                                                                                    
                        
                        
                        
                                                            Phase Angle Error CT PT Test Set